This safety feature prevents damaging the inverter while testing devices and equipment within the wattage range of the inverter.
IMPORTANT (Models
IMPORTANT: This inverter uses a nonsinusoidal waveform. Therefore we do not recommend you use it to power the following devices:
1.Switch mode power supplies
2.Linear power supplies
3.Class 2 transformers
4.Line filter capacitors
5.Shaded pole motors
6.Fan motors
7.Microwave ovens
8.Fluorescent and high intensity lamps (with a ballast)
9.Transformerless battery chargers
Doing so may cause the device to run warmer or overheat.
4.OPERATING INSTRUCTIONS (MODELS PI-70 and PI-140)
1.Push the
2.The LED indicator light should glow GREEN, verifying the inverter is receiving power.
3.Make sure the device to be operated is turned OFF.
4.Plug the device into the inverter AC outlet or USB port.
5.Turn the device on.
6.To disconnect, reverse the above procedure.
• 4 •