7.LED INDICATOR AND SHUTDOWN PROTECTION

engine. To maintain battery power, start the engine every 2 to 3 hours and let it run for approximately 30 minutes to recharge the battery.

Although it is not necessary to disconnect the inverter when turning over the engine, it may briefly cease to operate as the battery voltage decreases. While the inverter draws very low amperage when not in use, it should be unplugged to avoid battery drain.

7.LED INDICATOR AND SHUTDOWN PROTECTION

The LED glows GREEN automatically when plugged into a 12-volt DC source and will not glow under the following conditions (Note: On Model PI-120 a BLUE LED will glow):

1.When the power input from the vehicle’s battery drops to approximately 10-volts, low battery shutdown occurs and inverter shuts off. Solution: Recharge or replace the battery.

2.When the power input from the vehicle’s battery exceeds

15-volts, high voltage protection occurs. Solution: Reduce the voltage range to between 12-volts and 14-volts.

3.The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the inverter being used. Solution: Use a higher capacity inverter or lower rated device.

4.The case temperature becomes hot (exceeds 145°F). Solution: Allow the inverter to cool. Do not block the cooling slots or air flow over and through the inverter. Reduce the load on the inverter to the continuous rated output.

RESET: To reset after shutdown occurs, remove the 12-volt plug from the accessory outlet. Check the source of the problem and correct. Reinsert the 12-volt plug into the accessory outlet.

8.IF THE INVERTER FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated.

If the fuse does blow:

1.Disconnect the device or equipment immediately.

2.Find the source of the problem and repair it.