Do not modify the AC receptacle in any way.

Use only 40-amp or 50-amp fuses. (Replaced by certified technician only.)

This device does not include an internal Ground Fault Circuit Interrupter (GFCI). For GFCI protection, use a Coleman Cable 02822 GFCI outlet.

WARNING: Handling the cord on this product or cords as- sociated with accessories sold with this product, may expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.

Wash hands after handling.

Before Using PID-760 Power Inverter

It is important to know the continuous wattage of the device you plan to use with the inverter. The PID-760 must be used with devices drawing 760 watts or less. If the wattage is not marked on the device, an estimate can be made by multiply- ing the AC input current (Amps) by the AC voltage (110V).

Devices like TVs, fans or electric motors require additional power to start (commonly known as the “starting or peak power”). The PID-760 can supply a momentary surge in wattage; however even devices rated less than the maxi- mum 760 watts can exceed the inverters surge capability and cause an automatic overload shutdown.

Make sure the device you are using is compatible with a modified sine wave inverter.