TROUBLESHOOTING

PROBLEM: Alarm is On

Reason/Solution

1.Display shows SC. Device has a short circuit or demands too much surge power.

Cycle inverter power OFF and ON.

If problem persists, use a larger inverter or a smaller device.

Remove defective device.

See warranty and call Customer Service 800-621- 5485 (Hours: 7 a.m. – 4:30 p.m. CST).

2.Display shows Lob. 12 Volt battery too low. Recharge/replace low battery.

3.Display shows Voltage In between 10.5 and 11.0 Volts.

12 Volt battery is low. Recharge/replace low battery.

Inverter will automatically shut off after battery volt- age reaches 10.5 Volts.

4.Display shows Hi b. 12 Volt voltage is too high. If in a vehicle, repair/replace the alternator or charg- ing system.

Use a properly sized and rated 12 Volt battery.

If input voltage returns to 15 Volts or less, the in- verter will automatically restart.