LED DISPLAY

The LED readouts identify the current status of the PID-760.

VOLTAGE IN: Voltage of vehicle’s battery or Portable Power jump starter/DC power source.

VOLTAGE OUT: Voltage supplied to device through AC receptacle.

POWER OUT: Power or wattage supplied to device plugged into the inverter.

An audio alarm will sound when the following codes dis- play. To stop the alarm, press the ON/OFF LED Selector button:

bAd – Inverter is not functional. See warranty and call Customer Service 800-621-5485 (Hours: 7 a.m. – 4:30 p.m. CST).

Hib – Vehicle’s battery voltage is more than 15.5 volts. Inverter will automatically restart after the voltage drops below 15.5 volts.

hip – The continuous load demand from the device exceeds 760 watts.

HoT – Inverter is overheated and automatically turns off for a period of 1 – 3 minutes to cool. Make sure inverter is well ventilated. It will automatically restart after it cools.

Lob – Vehicle’s battery voltage is less than 10.5 volts.

SC – Short circuit, power surge or overload in the device.