H.

OUTPUT SELECTOR CONTROLS

 

 

Switches

 

 

 

 

Select

 

 

 

 

 

12v 40A

 

 

 

up

12v 2A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

 

#

 

 

#

 

 

1

 

 

2

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6v

 

40A

12v 200A

 

 

 

 

 

 

 

 

down

 

 

 

Start

 

 

or

 

 

 

 

 

 

 

 

 

6v 100A

Start

CHARGE TIME/MINUTES

Switch #1 Furthest left, Use this switch to select the 12volt 200 amp engine start (down) or the 12 volt 40 amp charge (up) position. The center switch (#2) must be in the (up) position when switch #1 is used.

Switch #2 (Center) Use this switch to select use of either switch #1 or switch #3. Down for switch #3 and up for switch #1.

Switch #3 Use this switch to select the 12 volt 2 amp charge (up) or the 6 volt 100 amp engine start (down). The center switch

(#2) must be in the down position to use switch #3.

TIMER: The main function of the timer is to prevent over charg- ing while allowing a battery time to obtain a satisfactory charge. To properly set the timer you must know the size of the battery in ampere hours or reserve capacity in minutes and the state of charge. Often the state of charge is not known, this is one rea- son why the timer was limited to 2.5 hours. With the aid of a battery load tester the state of charge can be obtained within a few seconds. For example, the average size automotive battery at a 50% state of charge will require 1 to 1.5 hours of charging at the 40 amp rate to reach the full charge state. For the same battery with the timer set to it’s maximum, 2.5 hours, over charg- ing will occur, but not likely cause harm to a battery that was other wise in good condition. When the charge state is not known, start out with a timer setting of 1 hour or less.

HOLD This position defeats the timer function, allowing for con- tinuous operation. Use when you want to charge more than 2.5 hours. This is normally the case when the 2 amp charge rate is selected. Be sure to monitor the charging and stop the charge when the battery is charged.

Full Charge

Discharged

40 AMP Reading

40 AMP Reading

0

10

20

30

40

200

 

CHARGING

 

 

START

 

 

DC AMPS

 

 

Sch487

 

 

 

 

4

The Ammeter indicates the amount of current measured in am- peres that is being drawn by the battery. For example, In the 40 amp charge rate a typical discharged battery will initially draw approximately 40 amps. As the battery continues to charge, current will taper to 15 to 20 amps at full charge. The Start area of the meter indicates a high rate of current being drawn from the charger. When cranking an engine, the starter motor draws upwards to 200 amps. The meter needle will be at the extreme right side of the start area. Sometimes a battery for the first few minutes of it’s charge will draw more than 40 amps, in this case the needle may be within but not to the extreme right side of the start area. The 2 amp charge rate may indicate some activity on the meter. The meter doesn’t have the resolution to display this low rate.