Specifications, Continued

Electrical Specifications

 

Item

Specification

 

 

 

 

 

 

Input voltage range

100 - 120 / 200 - 240 V AC

 

 

 

 

 

 

Output

Two non-isolated outputs 12 V DC

 

 

 

Output voltage: 12.25 ± 0.25 V (± 2%)

 

 

 

No adjustments necessary.

 

 

Maximum Spec. SMPS (with forced air-

6.25 A on each output (150 W output

 

 

cooling)

power)

 

 

Maximum Load in application

5.2 A (120 W output power)

 

 

 

 

 

 

Nominal load in application

4.2 A (96 W output power)

 

 

 

 

 

 

Minimal load

0.25 A (to start up the SMPS)

 

 

 

 

 

 

Output current limit for each 12 V

6.7 A (short circuit proof)

 

 

output

 

 

 

 

 

 

 

No derating over entire temperature

Nominal load from 0°C (32°F) up to

 

 

range

45°C (113°F)

 

 

Efficiency

83%

 

 

 

 

 

 

Switching frequency

± 66 kHz (Forward converter)

 

 

 

 

 

 

No load input power

Max. 5 W

 

 

 

 

 

 

Inrush current limitation with NTC

110 V: max. 50 A @ peak line

 

 

resistance

220 V: max. 100 A @ peak line

 

 

 

 

 

 

Fuse

4 A T (internal fuse size 5 x 20 mm)

 

 

 

 

 

 

 

 

 

© 2002 Scientific-Atlanta, Inc. All rights reserved.

A-2

Technical Specifications

6984278 Rev A

Page 36
Image 36
Scientific Atlanta Power Supply Unit manual Electrical Specifications