AFE325
Maintenance: Air Cooled Condenser, Bearings
1. Disconnect electrical power.
Electrical Shock Hazard
Disconnect electrical power before beginning.
2.Remove front louvered panel
3.Wipe the lint off the front of the condenser. If needed, clean the interior of the condenser.
4.Use pressurized air to blow the lint from the inside of the condenser. A vacuum cleaner hose should pick up most of the dust. Check for interior dirt. If needed, use coil cleaner to
5.Replace all panels and reconnect electrical power.
Auger and Bearing Inspection
While in most areas regular
Whenever the auger is removed, replacement of the water seal is recommended.
If a bearing requires replacement, the other bearing must also be replaced.
1.Unplug or disconnect electrical power.
2.Shut off the water supply.
3.Remove top panel.
4.Remove right side panel.
5.Drain the evaporator and reservoir.
6.Remove the two screws from the spout at the side of the evaporator.
7Remove screw holding spout plate to evaporator.
8.Remove spout.
9.Pull up on the pull ring to remove the auger. If it is difficult to pull:
A.Remove the breaker cover by taking the snap ring out.
B.Unscrew the auger bolt.
C.Use threaded rod or a slide hammer puller and screw into the auger, slide the weight up against the stop to remove the auger.
If the auger still will not move, bearing replacement is mandatory. See Bearing Removal and Replacement.