AFE325
Service Diagnosis
Problem | Possible Cause | Probable Correction |
No ice, nothing is operating. | Unit has no power. | Restore power. If breaker or fuse |
|
| tripped, check for overloaded |
|
| circuit or short circuit. |
|
|
|
| Master switch off | Switch unit on. Determine why |
|
| switch was off. |
|
|
|
| No water (water safety switch | Restore water supply. Check |
| open) | filters or strainer. |
|
|
|
| Spout switch open | Check bin thermostat for failure to |
|
| open and shut off machine. |
|
| Check spout for internal pitting. |
|
|
|
| Bin thermostat open | Check air temp, it must be over |
|
| 50oF. for thermostat to start unit. |
| Auger drive motor will not start. | Check windings of auger drive |
|
| motor. Check for seized gears. |
|
|
|
| Auger delay switch open | Replace auger delay. |
|
|
|
No ice, auger drive is operating. | Centrifugal switch is open. | Check/replace switch |
|
|
|
| Compressor will not start. | Check voltage. |
|
|
|
|
| Check start relay |
|
|
|
|
| Check start capacitor |
|
|
|
|
| Check compressor |
| Lack of refrigerant | Check system. Locate leak. |
|
| Recover remaining refrigerant, |
|
| replace drier, evacuate to 200 |
|
| microns and weigh in the system |
|
| charge. |
|
|
|
| No condensing | Fan not turning, or blade broken. |
Unit will not shut off. | Bin thermostat stuck closed. | Replace thermostat. |
Auger motor will not shut off. | Auger delay stuck | Replace auger delay |
|
|
|
| System pressures to low to switch | Check pressures. If low, check for |
| auger delay off. | restriction or leak. |
|
|
|