| AFE325 |
Service Diagnosis |
|
|
|
|
|
PROBLEM | POSSIBLE CAUSE | PROBABLE CORRECTION |
|
|
|
Unusual noise | Mineral scale in evaporator | Clean water system with ice |
|
| machine cleaner. |
|
|
|
| Auger coupling dry | Grease coupling |
|
|
|
| Auger coupling worn | Replace coupling and adapter |
|
| stand. |
|
|
|
| Bearings worn | Replace bearings and water seal. |
| Gearmotor loose on frame | Tighten bolts, check grommets |
| Low water level | Check water level in reservoir |
|
|
|
| Tubing vibrating | Check tubing for contact |
|
|
|
| Tooth on a gear missing | Check gears in auger drive |
|
|
|
| Compressor too loud | Replace compressor |
|
|
|
| Gear noise | Check gearmotor for oil leak |
Water leaks from cabinet | Evaporator water seal worn or | Replace seal and bearings |
| cracked |
|
| Tubing to evaporator leaks | Replace tubing/fittings |
| Drain leaks | Check drain tubes and fittings |
|
|
|
| External drain restricted | Clean out drain |
|
|
|
No refrigeration | Gearmotor does not turn | Check motor |
|
|
|
| Centrifugal switch does not close | Check switch |
| Fan motor does not turn | Check fan motor |
| Lack of refrigerant | Add refrigerant, if problem is |
|
| reduced, locate leak and repair it. |
| Compressor does not pump | Check/replace start capacitor |
|
|
|
|
| Check/replace start relay |
|
|
|
|
| Check/replace compressor |
|
|
|
August 1994