Scotsman Ice AFE325 specifications Problem, Possible Cause, Probable Correction, Service Diagnosis

Models: AFE325

1 23
Download 23 pages 57.84 Kb
Page 17
Image 17

 

 

AFE325

Service Diagnosis

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

PROBABLE CORRECTION

 

 

 

Unusual noise

Mineral scale in evaporator

Clean water system with ice

 

 

machine cleaner.

 

 

 

 

Auger coupling dry

Grease coupling

 

 

 

 

Auger coupling worn

Replace coupling and adapter

 

 

stand.

 

 

 

 

Bearings worn

Replace bearings and water seal.

 

Gearmotor loose on frame

Tighten bolts, check grommets

 

Low water level

Check water level in reservoir

 

 

 

 

Tubing vibrating

Check tubing for contact

 

 

 

 

Tooth on a gear missing

Check gears in auger drive

 

 

 

 

Compressor too loud

Replace compressor

 

 

 

 

Gear noise

Check gearmotor for oil leak

Water leaks from cabinet

Evaporator water seal worn or

Replace seal and bearings

 

cracked

 

 

Tubing to evaporator leaks

Replace tubing/fittings

 

Drain leaks

Check drain tubes and fittings

 

 

 

 

External drain restricted

Clean out drain

 

 

 

No refrigeration

Gearmotor does not turn

Check motor

 

 

 

 

Centrifugal switch does not close

Check switch

 

Fan motor does not turn

Check fan motor

 

Lack of refrigerant

Add refrigerant, if problem is

 

 

reduced, locate leak and repair it.

 

Compressor does not pump

Check/replace start capacitor

 

 

 

 

 

Check/replace start relay

 

 

 

 

 

Check/replace compressor

 

 

 

August 1994