What to do before calling for service

CU1526, CU2026, CU3030

User Manual

What to do before calling for service

Reasons the machine might shut itself off:

Lack of water.

Freeze cycle takes too long.

Harvest cycle takes too long.

To Manually Reset the machine.

Push and release the Off button.

Push and release the On button.

High discharge temperature.

Controller self test failure.

Check the following:

1.Has the water supply to the ice machine or building been shut off? If yes, the ice machine will automatically restart within 25 minutes after water begins to flow to it.

2.Has power been shut off to the ice machine? If yes, the ice machine will automatically restart when power is restored.

3.Has someone shut the water off to a water cooled unit? If yes, after the water supply has been restored the ice machine may need to be manually reset.

4.Is the curtain open because some ice is stuck under it? If so, remove the ice and the machine should start in a few minutes.

Note: Curtain can be removed & replaced anytime the machine is in a standby mode or when it is in a freeze cycle. However, removal of the curtain during freeze will result in water flowing into the bin. Removal of the curtain during harvest terminates harvest at that point and, if left off, will result in the machine shutting off.

To Shut the Machine Off:

Move the On Off switch to the Off position.

or, at the controller

Push and hold the Off button for 3 seconds or until the machine stops.

Power Status Water De-scale

 

Sanitize

On

 

Off

 

 

 

Technician Section

 

 

 

 

Code

Description

 

 

 

F

. . . . . . . . . .

Freeze Cycle

 

 

 

F

flashes . . . .

Freeze Cycle is Pending

Manual

Clean

 

H

. . . . . . . . . .

Harvest Cycle

Harvest

Code

 

H

flashes . . . .

Manual Harvest

 

 

b

 

Bin is Full

 

Display

 

. . . . . . . . . .

 

 

C

 

Clean Cycle

 

 

 

. . . . . . . . . .

Control Operation - See Manual

L

. . . . . . . . . .

Board Locked

Water Light On - Restore water supply to

d

. . . . . . . . . .

Test Mode

O

 

Off

machine.

 

 

. . . . . . . . . .

 

 

E

 

Self Test Failed

De-Scale Light On - Clean and sanitize

. . . . . . . . . .

1

flashes. . . .

Max Freeze - Retrying

machine.

 

 

1 .

. . . . . . . . . .

Max Freeze Time Shut Down

Flush Setting - To Change: Depress Off

2

flashes . . . .

Max Harvest - Retrying

for 3 seconds. Press On to select purge

2

. . . . . . . . . .

Max Harvest Time Shut Down

(1-5) setting or A for Automatic.

 

3

. . . . . . . . . .

Slow Water Fill

Test Mode - Depress Off for 3 seconds,

4

. . . . . . . . . .

High Discharge Temp

5

 

Sump Temp Sensor Failure

then depress Clean for 3 seconds.

. . . . . . . . . .

7

 

Discharge Temp Sensor Failure

Recall Diagnostic Codes - Depress Off

. . . . . . . . . .

8

flashes .

Short Freeze - Retrying

for 3 seconds. Press Harvest repeatedly

8

 

Short Freeze - Thin ice

to go from most recent to oldest of 10.

All 4 Upper Lights Flashing - Unit Remotely

Reset from Code 1, 2, 4 or 8 - Depress

Locked Out - Contact Leasing Company

Off then Depress On.

Component Operation Indicator Lights

 

 

02-4302-01

 

 

 

 

 

May 2008

Page 16

Page 17
Image 17
Scotsman Ice CU2026, CU1526 What to do before calling for service, To Manually Reset the machine, Check the following