NME454, 654 & FME504, 804
BEARING MAINTENANCE
The bearing in the breaker should also be checked | unscrewing the auger stud | |||
at least two times per year. | ||||
| ||||
A. Check the bearing by: |
| |||
removing the ice chute cover |
| |||
|
|
| ||
| Chute Cover |
|
|
Auger Stud
Cap Screw
unscrewing the ice sweep
Ice Sweep
removing the water shed & unscrewing the breaker cover (left hand threads).
Breaker
Cover
Inspect the bearing. There should be plenty of grease in sight. If grease is needed the bearing and breaker should be removed to check the action of the bearing. It should rotate smoothly. To remove the breaker remove the lower ice chute then take out all four allen head cap screws and pull the breaker off the auger and evaporator.
If the bearing only needs grease, inject grease into the bearing using Scotsman grease needle pn
See Removal and Replacement section to replace bearing or seals.
Bearing | Needle, pn | |
|
Off
Reverse to reassemble.
January 2007
Page 12