NME454, 654 & FME504, 804
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Air Cooled Models: Use 3 8" O.D. copper tubing to connect cold potable water to the 3 8" male flare fitting at the back of the cabinet. Install a hand valve near the machine to control the water supply. Water Treatment: In most areas, a water filter of some type will be useful. In areas where the water is highly concentrated with minerals the water should be tested by a water treatment specialist, and the recommendations of the specialist regarding filtration and/or treatment should be followed.
Water Cooled Models: Connect a separate 3 8" O.D. copper line, with a separate hand valve, to the 3 8" FPT condenser inlet at the back of the cabinet. The water pressure to all lines must always be above 20 PSIG, and below 80 PSIG.
WATER
COOLED
CONDENSER
INLET
HAND
VALVE
Drains
Air Cooled Models: Connect a drain tube to the ¾" FPT drain at the back of the cabinet, the drain line is of the gravity type, and ¼ inch per foot fall is an acceptable pitch for the drain tubing. There should be a vent at the highest point of the drain line, and the ideal drain receptacle would be a trapped and vented floor drain.
Use only ¾" rigid tubing.
Water Cooled Models: In addition to the above mentioned drain, a separate condenser drain must be installed. Connect it to the ½" condenser drain connection at the back of the cabinet.
Storage Bin: Install a separate gravity type drain, similar to the air cooled drain. Insulation of this drain line is recommended.
HAND | VENTED |
VALVE |
|
| AIR COOLED |
| MODELS |
FIELD
SUPPLIED
WATER CONDENSER VENTED
FILTER DRAIN DRAIN
WATER
INLET
FILTER