Scotsman Ice FME804, NME454 For The Plumber, Conform To All Applicable Codes, Water Inlet, Drains

Models: FME504 FME804 NME654 Flake and Nugget Ice Machine NME454

1 16
Download 16 pages 49.74 Kb
Page 7
Image 7
FOR THE PLUMBER

NME454, 654 & FME504, 804

FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

Air Cooled Models: Use 3 8" O.D. copper tubing to connect cold potable water to the 3 8" male flare fitting at the back of the cabinet. Install a hand valve near the machine to control the water supply. Water Treatment: In most areas, a water filter of some type will be useful. In areas where the water is highly concentrated with minerals the water should be tested by a water treatment specialist, and the recommendations of the specialist regarding filtration and/or treatment should be followed.

Water Cooled Models: Connect a separate 3 8" O.D. copper line, with a separate hand valve, to the 3 8" FPT condenser inlet at the back of the cabinet. The water pressure to all lines must always be above 20 PSIG, and below 80 PSIG.

WATER

COOLED

CONDENSER

INLET

HAND

VALVE

Drains

Air Cooled Models: Connect a drain tube to the ¾" FPT drain at the back of the cabinet, the drain line is of the gravity type, and ¼ inch per foot fall is an acceptable pitch for the drain tubing. There should be a vent at the highest point of the drain line, and the ideal drain receptacle would be a trapped and vented floor drain.

Use only ¾" rigid tubing.

Water Cooled Models: In addition to the above mentioned drain, a separate condenser drain must be installed. Connect it to the ½" condenser drain connection at the back of the cabinet.

Storage Bin: Install a separate gravity type drain, similar to the air cooled drain. Insulation of this drain line is recommended.

HAND

VENTED

VALVE

 

 

AIR COOLED

 

MODELS

FIELD

SUPPLIED

WATER CONDENSER VENTED

FILTER DRAIN DRAIN

WATER

INLET

FILTER

January 2007

Page 6

Page 7
Image 7
Scotsman Ice FME804, NME654 For The Plumber, Conform To All Applicable Codes, Water Inlet, Drains, NME454, 654 & FME504