Bryant 593C warranty SPECIFICATIONS Continued, Unit Size, 042-C,D, 048-C, 060-C, Electrical

Models: 593C

1 28
Download 28 pages 55.53 Kb
Page 5
Image 5

SPECIFICATIONS Continued

UNIT SIZE

042-C, D

048-C

 

060-C

Operating Weight (Lb)

206

199

 

217

ELECTRICAL

 

 

 

 

Unit Volts—Hertz—Phase

 

208–230—60—1

 

 

Operating Voltage Range*

 

197—253

 

 

Compressor— Rated Load Amps

19.0

24.4

 

28.8

 

Locked Rotor Amps

105.0

140.0

 

165.0

Condenser Fan Motor—Full Load Amps

1.4

1.4

 

1.4

Min Unit Ampacity for Wire Sizing

25.2

31.9

 

37.4

Min Wire Size (75°C Copper) AWG†

10

10

 

8

Min Wire Size (60°C Copper) AWG†

10

8

 

8

Max Wire Length (Ft) (75°C Copper)‡

73

59

 

78

Max Wire Length (Ft) (60°C Copper)‡

77

97

 

82

Max Branch Circuit Fuse Size**

40

50

 

60

COMPRESSOR and REFRIGERANT

 

 

 

 

Compressor—Manufacturer and Type

Copeland Reciprocating

Millennium Scroll

 

Millennium Scroll

Temperature and Current Protection

Internal Line Break

Internal Line Break and Dome Thermostat

Refrigerant—Type and Amount (Lb)††

R-22 and 5.51

R-22 and 7.63

 

R-22 and 10.63

CONDENSER COIL and FAN

 

 

 

 

Coil Face (Sq Ft)

12.2

15.2

 

18.3

Fins per In.—Rows—Circuits

20—1—2

25—1—3

 

25—1—4

Fan Motor—HP, Type, and RPM

 

1/4 PSC and 1100

 

 

Volts—Hertz—Phase

 

208/230—60—1

 

 

Condenser Airflow (CFM)

 

3000

 

 

OPTIONAL EQUIPMENT

 

 

 

 

Support Feet

 

KSASF0101AAA

 

 

Coastal Filter

 

KAACF0801MED

 

 

Time Delay Relay

 

KAATD0101TDR

 

 

Cycle Protector

 

KSACY0101AAA

 

 

Crankcase Heater

Standard

 

KAACH1201AAA

Start Assist—Capacitor/Relay Type

KSAHS1301AAA

 

KSAHS1601AAA

Start Assist—PTC Type

 

KAACS0201PTC

 

 

Sound Hood

KSASH1201COP

 

KSASH2001CYL

TXV Kit (RPB)

KAATX0501RPB

KAATX0601RPB

 

KAATX0701RPB

TXV Kits (Hard Shutoff)

KSATX0601HSO

 

KSATX0701HSO

Low-Pressure Switch

 

KAALP0101LPS

 

 

High-Pressure Switch

 

KSAHI0101HPS

 

 

Filter Drier

 

P502-8163S (RCD)

 

 

Evaporator Freeze Thermostat**

 

KAAFT0101AAA

 

 

Liquid-Line Solenoid Valve

 

KAALS0101LLS

 

 

Winter Start Control**

 

KAAWS0101AAA

 

 

Low-Ambient Kit

 

KSALA0201R22

 

 

MotorMaster® Control††

 

32LT660004 (RCD)

 

 

Ball Bearing Fan Motor

 

HC40GE232 (RCD)

 

 

Thermostat, Auto Changeover,

 

 

 

 

Non-Programmable, °F/°C,

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

TSTATBBNAC01-B

 

 

Thermostat, Auto Changeover,

 

 

 

 

7-Day Programmable, °F/°C,

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

TSTATBBPAC01-B

 

 

Builder’s Thermostat, Manual

 

 

 

 

Changeover, Non-Programmable,

 

 

 

 

°F/°C, 1-Stage Heat, 1-Stage Cool

 

TSTATBBBAC01-B

 

 

Thermidistat™ Control—Programmable/

 

 

 

 

Non-Programmable Thermostat with

 

 

 

 

Humidity Control

 

TSTATBBPRH01-B

 

 

Outdoor Air Temperature Sensor

 

TSTATBBSEN01-B

 

 

Backplate for Non-Programmable

 

 

 

 

Thermostat

 

TSTATXXNBP01

 

 

Backplate for Programmable Thermostat

 

TSTATXXPBP01

 

 

Backplate for Builder’s Thermostat

 

TSTATXXBBP01

 

 

Thermostat Conversion Kit (4 to 5 wire)

 

 

 

 

— 10 Pack

 

TSTATXXCNV10

 

 

*Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.

† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).

The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).

‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.

**Fan motor with ball bearings required. See Low-ambient controller Installation Instructions for application.

NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

—5—

Page 5
Image 5
Bryant 593C warranty SPECIFICATIONS Continued, Unit Size, 042-C,D, 048-C, 060-C, Electrical, COMPRESSOR and REFRIGERANT