COMBINATION RATINGS Continued
|
|
|
| FACTORY- |
|
| BRYANT GAS |
|
|
|
| TOT. | SUPPLIED |
|
| FURNACE OR |
|
UNIT | INDOOR |
| CAP. | ENHANCE- | STANDARD |
| ACCESSORY | ACCESSORY |
MODEL |
| BTUH | MENT | RATING |
| TDR† | TXV‡ | |
| CC5A/CD5AW060* |
| 57,000 | NONE | 10.20 |
| 10.50 | 10.50 |
| CC5A/CD5AA060 |
| 54,500 | NONE | 10.00 |
| 10.20 | 10.20 |
| CE3AA060 |
| 57,500 | NONE | 10.20 |
| 10.50 | 10.50 |
| CK3BA060 |
| 54,500 | NONE | 10.00 |
| 10.20 | 10.20 |
| CK5A/CK5BA060 |
| 54,500 | NONE | 10.00 |
| 10.20 | 10.20 |
| CK5A/CK5BN060 |
| 54,500 | NONE | 10.00 |
| 10.20 | 10.20 |
| CK5A/CK5BX060 |
| 57,000 | NONE | 10.20 |
| 10.50 | 10.50 |
| F(A,B)4(A,B)N(F,B)060 |
| 57,500 | TDR | 10.00 |
| — | 10.00 |
| FB4(A,B)NB070 |
| 58,500 | TDR | 10.50 |
| — | 10.50 |
| FC4(B,C)NB070 |
| 58,500 | TDR & TXV | 10.50 |
| — | — |
| FC4(B,C)N(F,B)060 |
| 57,500 | TDR & TXV | 10.00 |
| — | — |
| FG3AAA060 |
| 56,500 | NONE | 10.20 |
| 10.50 | 10.50 |
| FK4(C,D)NB006 |
| 58,000 | TDR & TXV | 11.00 |
| — | — |
|
| COILS + 315(A,J)AV066110 |
|
| ||||
| CC5A/CD5AA060 |
| 55,000 | TDR | 10.5 |
| 10.5 | 9 |
| CE3AA060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.3 |
| CK3BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 |
CK5A/CK5BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 | |
CK5A/CK5BT060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 | |
| CK5A/CK5BX060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.4 |
|
| COILS + 315(A,J)AV066135 |
|
| ||||
| CC5A/CD5AA060 |
| 55,000 | TDR | 10.5 |
| 10.5 | 9 |
| CC5A/CD5AW060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.25 |
| CE3AA060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.3 |
| CK3BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 |
| CK5A/CK5BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 |
| CK5A/CK5BT060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.15 |
| CK5A/CK5BX060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.4 |
|
| COILS + 315(A,J)AV066155 |
|
| ||||
| CC5A/CD5AA060 |
| 55,000 | TDR | 10.5 |
| 10.5 | 9.1 |
| CC5A/CD5AW060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.3 |
| CE3AA060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.35 |
| CK3BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.2 |
| CK5A/CK5BA060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.2 |
| CK5A/CK5BT060 |
| 56,000 | TDR | 10.5 |
| 10.5 | 9.2 |
| CK5A/CK5BX060 |
| 56,500 | TDR | 10.5 |
| 10.5 | 9.45 |
* Tested combination.
†In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory
‡Based on computer simulation, TXV must be hard shutoff type.
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other com- binations are determined under DOE computer simulation procedures.
3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.