Bryant 593C warranty COMBINATION RATINGS Continued

Models: 593C

1 28
Download 28 pages 55.53 Kb
Page 14
Image 14

COMBINATION RATINGS Continued

 

 

 

 

FACTORY-

 

 

BRYANT GAS

 

 

 

 

TOT.

SUPPLIED

 

 

FURNACE OR

 

UNIT

INDOOR

 

CAP.

ENHANCE-

STANDARD

 

ACCESSORY

ACCESSORY

SIZE-SERIES

MODEL

 

BTUH

MENT

RATING

 

TDR†

TXV‡

 

CC5A/CD5AW060*

 

57,000

NONE

10.20

 

10.50

10.50

 

CC5A/CD5AA060

 

54,500

NONE

10.00

 

10.20

10.20

 

CE3AA060

 

57,500

NONE

10.20

 

10.50

10.50

 

CK3BA060

 

54,500

NONE

10.00

 

10.20

10.20

 

CK5A/CK5BA060

 

54,500

NONE

10.00

 

10.20

10.20

 

CK5A/CK5BN060

 

54,500

NONE

10.00

 

10.20

10.20

 

CK5A/CK5BX060

 

57,000

NONE

10.20

 

10.50

10.50

 

F(A,B)4(A,B)N(F,B)060

 

57,500

TDR

10.00

 

10.00

 

FB4(A,B)NB070

 

58,500

TDR

10.50

 

10.50

 

FC4(B,C)NB070

 

58,500

TDR & TXV

10.50

 

 

FC4(B,C)N(F,B)060

 

57,500

TDR & TXV

10.00

 

 

FG3AAA060

 

56,500

NONE

10.20

 

10.50

10.50

 

FK4(C,D)NB006

 

58,000

TDR & TXV

11.00

 

 

 

COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE

 

 

 

CC5A/CD5AA060

 

55,000

TDR

10.5

 

10.5

9

 

CE3AA060

 

56,500

TDR

10.5

 

10.5

9.3

 

CK3BA060

 

56,000

TDR

10.5

 

10.5

9.15

060-C

CK5A/CK5BA060

 

56,000

TDR

10.5

 

10.5

9.15

CK5A/CK5BT060

 

56,000

TDR

10.5

 

10.5

9.15

 

CK5A/CK5BX060

 

56,500

TDR

10.5

 

10.5

9.4

 

 

COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE

 

 

 

CC5A/CD5AA060

 

55,000

TDR

10.5

 

10.5

9

 

CC5A/CD5AW060

 

56,000

TDR

10.5

 

10.5

9.25

 

CE3AA060

 

56,500

TDR

10.5

 

10.5

9.3

 

CK3BA060

 

56,000

TDR

10.5

 

10.5

9.15

 

CK5A/CK5BA060

 

56,000

TDR

10.5

 

10.5

9.15

 

CK5A/CK5BT060

 

56,000

TDR

10.5

 

10.5

9.15

 

CK5A/CK5BX060

 

56,500

TDR

10.5

 

10.5

9.4

 

 

COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE

 

 

 

CC5A/CD5AA060

 

55,000

TDR

10.5

 

10.5

9.1

 

CC5A/CD5AW060

 

56,000

TDR

10.5

 

10.5

9.3

 

CE3AA060

 

56,500

TDR

10.5

 

10.5

9.35

 

CK3BA060

 

56,000

TDR

10.5

 

10.5

9.2

 

CK5A/CK5BA060

 

56,000

TDR

10.5

 

10.5

9.2

 

CK5A/CK5BT060

 

56,000

TDR

10.5

 

10.5

9.2

 

CK5A/CK5BX060

 

56,500

TDR

10.5

 

10.5

9.45

* Tested combination.

In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use

either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.

Based on computer simulation, TXV must be hard shutoff type.

NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.

2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other com- binations are determined under DOE computer simulation procedures.

3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

—14—