ACCESSORY DESCRIPTION AND USE (Listed Alphabetically) Continued
17.Time Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
18.Winter Start Control
An SPST delay relay which bypasses the
SUGGESTED USE: All air conditioners where
ACCESSORY USAGE GUIDELINE
| REQUIRED FOR | REQUIRED FOR | REQUIRED FOR | |
| SEA COAST | |||
| APPLICATIONS | APPLICATIONS* | APPLICATIONS | |
ACCESSORY | (Below 55°F) | (Over 50 Ft) | (Within 2 Miles) | |
Crankcase Heater | Yes | Yes | No | |
Evaporator Freeze Thermostat | Yes | No | No | |
Winter Start Control | Yes† | No | No | |
Accumulator | No | No | No | |
Compressor Start Assist | Yes | Yes | No | |
Capacitor and Relay | ||||
|
|
| ||
MotorMaster® Control |
|
|
| |
or | Yes | No | No | |
|
|
| ||
Wind Baffle | See | No | No | |
Coastal Filter | No | No | Yes | |
Support Feet | Recommended | No | Recommended | |
| See |
| ||
or | No | Application | No | |
Hard Shutoff TXV |
| Guideline |
| |
Ball Bearing Fan Motor | Yes‡ | No | No |
*For tubing line sets greater than 50 ft and/or 20 ft vertical differential, refer to Residential
† Only when
‡ Required for
SOUND POWER (dBA)
| Sound |
|
| OCTAVE BAND CENTER FREQUENCY (Hz) |
|
| ||
Unit | Level |
|
|
|
|
|
|
|
Size | (dBA) | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
76 | 54.0 | 63.5 | 66.0 | 66.0 | 65.0 | 62.5 | 55.5 | |
78 | 53.0 | 69.0 | 69.5 | 71.0 | 68.5 | 64.5 | 60.5 | |
80 | 53.5 | 64.0 | 66.5 | 69.5 | 69.0 | 65.0 | 58.5 | |
80 | 57.0 | 65.5 | 71.0 | 75.0 | 71.0 | 67.5 | 62.0 | |
80 | 62.5 | 69.0 | 72.0 | 75.0 | 72.0 | 69.5 | 62.5 | |
82 | 63.0 | 71.0 | 71.0 | 72.0 | 73.5 | 68.0 | 63.5 | |
82 | 61.5 | 69.5 | 71.0 | 74.5 | 70.0 | 69.0 | 66.0 |