2.8.6.1Operating vibration

The maximum random vibration levels that the drive may experience while meeting the performance standards specified in this document are specified below. This specification does not cover connection issues that may result from testing at this level.

20–2000 Hz

11.08 Grms

2.8.6.2Nonoperating vibration

The maximum random nonoperating vibration levels that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation are specified below.

20–2000 Hz

11.08 Grms

2.9ELECTROMAGNETIC IMMUNITY

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5 Radio frequency environments

TEST

DESCRIPTION

PERFORMANCE

REFERENCE

LEVEL

STANDARD

 

 

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 1000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine

A

EN 61000-4-6: 97

 

 

 

 

Voltage dips, interrupts

0% open, 5 seconds

C

EN 61000-4-11: 94

 

0% short, 5 seconds

C

 

 

40%, 0.10 seconds

C

 

 

70%, 0.01 seconds

B

 

 

 

 

 

SEAGATE 600 SSD PRODUCT MANUAL, REV. A

12

Page 16
Image 16
Seagate ST480HM000 Operating vibration, Nonoperating vibration, Electromagnetic Immunity, Radio frequency environments