6.4.2Relative humidity

The values below assume that no condensation on the drive occurs.

a.Operating

5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.

b.Non-operating

5% to 95% non-condensing relative humidity.

6.4.3Effective altitude (sea level)

a.Operating

–1,000 to +10,000 feet (–305 to +3,048 meters)

b.Non-operating

–1,000 to +40,000 feet (–305 to +12,210 meters)

6.4.4Shock and vibration

Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement.

The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 11, and in accordance with the restrictions of Section 8.3.

6.4.4.1Shock

a.Operating—normal

The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding:

15 Gs at a duration of 11 msec (half sinewave)

25 Gs at a duration of 2 msec (half sinewave)

60 Gs at a duration of 2 msec (half sinewave) when performing reads only

Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.

b.Operating—abnormal

Equipment, as installed for normal operation, does not incur physical damage while subjected to intermit- tent shock not exceeding 40 Gs at a duration of 11 msec (half sinewave). Shock occurring at abnormal lev- els may promote degraded operational performance during the abnormal shock period. Specified operational performance will continue when normal operating shock levels resume. Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.

c.Non-operating

The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.

The drive subjected to nonrepetitive shock not exceeding the three values below, shall not exhibit device damage or performance degradation.

80 Gs at a duration of 11 msec (half sinewave)

300 Gs at a duration of 2 msec (half sinewave)

150 Gs at a duration of 0.5 msec (half sinewave)

Shock may be applied in the X, Y, or Z axis.