Seagate ST3250823ACE, ST3200826ACE Acoustics, Electromagnetic immunity, Nonoperating vibration

Models: ST3300831ACE ST3250823ACE ST3200826ACE ST3400832ACE

1 50
Download 50 pages 48.61 Kb
Page 21
Image 21

2.8.6.2Nonoperating vibration

The following table lists the maximum nonoperating vibration that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation.

5–22 Hz

0.25 G

 

 

22–350 Hz

5.0 Gs

 

 

2.9Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea- surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

Table 4:

Operating acoustics

 

 

 

 

Acoustic mode

 

 

 

 

 

 

Models

 

Idle

Operational

 

 

 

ST3400832ACE

2.6 bels (typ)

2.8 bels (typ)

 

 

2.8 bels (max)

3.0 bels (max)

 

 

 

ST3300831ACE

2.4 bels (typ)

2.8 bels (typ)

ST3250823ACE

2.7 bels (max)

3.0 bels (max)

ST3200826ACE

 

 

 

 

 

 

2.10Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Radio frequency environments

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air:

B

EN 61000-4-2: 95

 

 

± 8 kV

 

 

 

 

 

 

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse

 

 

 

 

modulation @ 200 Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on

B

EN 61000-4-4: 95

 

 

external I/O

 

 

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV com-

B

EN 61000-4-5: 95

 

 

mon, AC mains

 

 

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms,

A

EN 61000-4-6: 97

 

 

80% AM with 1 kHz sine

 

 

 

 

 

 

 

DB35 Series Product Manual, Rev. B

11

Page 21
Image 21
Seagate ST3250823ACE, ST3200826ACE manual Acoustics, Electromagnetic immunity, Nonoperating vibration, Operating acoustics