2.11Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Radio frequency environments

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air:

B

EN 61000-4-2: 95

 

 

± 8 kV

 

 

 

 

 

 

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse

 

 

 

 

modulation @ 200 Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on

B

EN 61000-4-4: 95

 

 

external I/O

 

 

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV com-

B

EN 61000-4-5: 95

 

 

mon, AC mains

 

 

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms,

A

EN 61000-4-6: 97

 

 

80% AM with 1 kHz sine

 

 

 

 

 

 

Voltage dips, interrupts

0% open, 5 seconds

C

EN 61000-4-11: 94

 

 

0% short, 5 seconds

C

 

 

 

40%, 0.10 seconds

C

 

 

 

70%, 0.01 seconds

B

 

2.12

Reliability

 

 

 

Nonrecoverable read errors

1 per 1014 bits read, max.

Annualized Failure Rate (AFR)

0.68% (nominal power, 25°C ambient temperature)

 

 

Contact start-stop cycles

50,000 cycles

 

 

(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle)

Warranty

 

5 years on distribution units.

 

 

To determine the warranty for a specific drive, use a web browser to access the fol-

 

 

lowing web page:

 

 

www.seagate.com/support/service/

 

 

From this page, click on the “Verify Your Warranty” link. You will be asked to provide

 

 

the drive serial number, model number (or part number) and country of purchase.

 

 

The system will display the warranty information for your drive.

 

 

Preventive maintenance

None required.

 

 

 

2.13Agency certification

2.13.1Safety certification

The drives are recognized in accordance with UL 1950 and CSA C22.2 (950) and meet all applicable sections of IEC950 and EN 60950 as tested by TUV North America.