Seagate ST340015ACE manual Reliability, Performance Reference Test Description Level Standard

Models: ST340015ACE

1 58
Download 58 pages 51.73 Kb
Page 25
Image 25

Barracuda 5400.1 Product Manual, Rev. G

17

2.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

 

 

Performance

Reference

Test

Description

level

standard

 

 

 

 

 

 

 

 

Electrostatic

Contact, HCP, VCP: ± 4 kV;

B

EN 61000-4-2: 95

discharge

Air: ± 8 kV

 

 

 

 

 

 

Radiated RF

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

immunity

80% AM with 1 kHz sine

 

ENV 50204: 95

 

900 MHz, 3 V/m, 50% pulse

 

 

 

modulation @ 200 Hz

 

 

 

 

 

 

Electrical fast

± 1 kV on AC mains, ± 0.5

B

EN 61000-4-4: 95

transient

kV on external I/O

 

 

 

 

 

 

Surge

± 1 kV differential, ± 2 kV

B

EN 61000-4-5: 95

immunity

common, AC mains

 

 

 

 

 

 

Conducted

150 kHz to 80 MHz, 3 Vrms,

A

EN 61000-4-6: 97

RF immunity

80% AM with 1 kHz sine

 

 

 

 

 

 

Voltage dips,

0% open, 5 seconds

C

EN 61000-4-11: 94

interrupts

0% short, 5 seconds

C

 

 

40%, 0.10 seconds

C

 

 

70%, 0.01 seconds

B

 

 

 

 

 

2.13

Reliability

 

Nonrecoverable read errors

1 per 1014 bits read, max.

Mean time between failures

600,000 power-on hours .

 

 

(nominal power, 25°C ambient temperature)

Service life

 

The drive shall have a useful service life of five years.

Contact start-stop cycles

50,000 cycles.

 

 

(at nominal voltage and temperature, with 60 cycles

 

 

per hour and a 50% duty cycle)

Preventive maintenance

None required.