| Barracuda 9LP Installation Guide, Rev. E | 
 | 19 | ||||||
| Table 2c. DC power requirements (Amps), multimode | ||||||||
| 
 | 
 | (SE/LVD) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | ST39173LW/LC | ST34573LW/LC | ||
| Voltage | +5V | +12V | +5V | +12V | ||||
| Regulation [5] | ±5% | ±5%[2] | ±5% | ±5%[2] | ||||
| Max. operating current | 
 | 
 | 
 | 
 | ||||
| DC [1] | 1.4 | 0.95 | 1.4 | 0.95 | ||||
| Avg. idle current | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | [1] | 
 | 
 | 0.75 | 0.5 | 0.75 | 0.5 | 
| DCX | 
 | 
 | ||||||
| Max. starting current | 
 | 
 | 
 | 
 | ||||
| (peak DC) [3] | 1.2 | 1.7 | 1.2 | 1.7 | ||||
| (peak AC) [3] | — | 2.9 | — | 2.9 | ||||
| Delayed motor | 
 | 
 | 
 | 
 | ||||
| start (max) [1][4] | 0.65 | 0.06 | 0.65 | 0.06 | ||||
| Peak operating current | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | [1][6] | 1.2 | 0.9 | 1.2 | 0.9 | ||
| Typical DCX | ||||||||
| Maximum DC [1] | 1.4 | 0.95 | 1.4 | 0.95 | ||||
| Maximum (peak) | 1.7 | 2.4 | 1.7 | 2.4 | ||||
[1]Measured with an average reading DC ammeter. Instanta- neous +12V current peaks will exceed these values.
[2]A 
[3]See the +12V current profile in the Barracuda 9LP Product Manual (publication number 77767517).
[4]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.