91
Electrical Specifications - Power, continued
Internal Power
Dissipation
Specifications
Table
The following table provides 17S internal power dissipat ion at maximum continuous
output power. This information may be useful to size the thermal capability of the
mounting cabinet.
Note: These power dissipations are measured at maximum continuous power and
should be considered worst case. Often in sizing servo systems, factors such as
profile duty cycle may reduce these numbers. These values do not include power
dissipated in the Regen resistor. This is applicati on- speci fic a nd m ust be c alcul ated
separately.
Quiescent dissipation when output stage is disabled is 15 W
Model Number Power
MHDS1004N00 30 W
MHDS1008N00 40 W
MHDS1017N00 60 W
MHDS1028N00 90 W
MHDS1056N00 200 W