Wire Specifications (Recommended)

Wire

Specifications The following table lists the recommended wire spe cifications. Use only copper wire

with insulation rated at 75°C or greater, unless otherwise specified.

Item Drive Model No. Wire Size Notes
AC mains MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00
1.5 mm2 (14 AWG)
MHDS1056N00 4.0 mm2 (12 AWG)
Protective earth All 4.0 mm2 (12 AWG)
DC Link MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00
1.5 mm2 (14 AWG) Shielded for lengths
greater than 20cm
MHDS1056N00 4.0 mm2 (12 AWG) Shielded for lengths
greater than 20cm
Analog signals All 0.25 mm2 (22 AWG)
minimum
Twisted pairs,
shielded
Digital I/O and Fault
Relay All 0.5 mm2 (20 AWG)
minimum
Brake All 1.0 mm2 (18 AWG)
minimum
Shielded
Bias power All 2.5 mm2 (14 AWG)
maximum
Optional external
Regen resistor All 1.5 mm2 (14 AWG) High temperature
insulation (155°C or
greater)