90
Electrical Specifications - Power, continued
Motor Output Specifications TableThe following table provides 17S motor output specifications.Note: Motors must be compatible with following table:
Continued on next page
Parameter Type Model Number Current
Output current (RMS) Continuous MHDS1004N00* 1.5 A
MHDS1008N00 3 A
MHDS1017N00 6 A
MHDS1028N00 10 A
MHDS1056N00 20 A
Intermittent** MHDS1004N00 3 A
MHDS1008N00 6 A
MHDS1017N00 12 A
MHDS1028N00 20 A
MHDS1056N00 40 A
Switching frequency 8 kHz ± 0.1%
Cable length*** 75 m (maximum)
Maximum cable capacitance (motor
phase to ground or shield) 150 pF/m
* For single phase main connection, the output current is limited to the output
current specifed above or 4 amps, whichever is lower.
** Duration depends on settings in Unilink.
*** Cable lengths exceeding 25 m require the use of motor choke AM0FIL001V056
Motor Inductance:
Model Min (mH) Max (mH)
MHDS1004N00 16 400
MHDS1008N00 8 200
MHDS1017N00 4 100
MHDS1028N00 3.5 60
MHDS1056N00 1.5 30