Connection diagram for Lexium 17S

Reference Safety Instructions

 

 

 

 

 

 

 

 

 

4

+ +/-10V speed

and Use As Directed!

thermal control

 

 

 

 

X1

Analog 1 in +

 

included

 

 

 

 

 

5

setpoint1

 

15

 

high

 

 

 

Analog 1 in -

referenced to GND

 

 

 

 

 

 

Sine-Cosine

 

 

resolution

 

 

Analog Com

1

GND

Encoder

 

 

single /

 

 

 

6

 

 

 

multiturn

 

Analog 2 in +

+ +/-10V speed

 

 

 

 

 

 

 

 

Analog 2 in -

7

setpoint2

 

 

 

 

 

 

 

 

referenced to GND

 

thermal control

 

 

 

 

 

 

 

 

 

 

 

 

X2

 

Reserved

8

 

 

included

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

8

 

 

 

 

 

 

Analog Com

GND

Resolver

 

Resolver

 

 

 

 

 

9

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X3

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O Com

18

I/O-GND

 

U2

6

U

 

 

X9

 

 

 

 

 

 

 

 

 

 

 

+24V referenced

 

V2

5

V

 

 

 

 

 

 

 

13

to 0V/GND

 

 

 

 

 

 

 

 

Input 3

 

 

W

4

W

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

M

PE

3

 

 

 

 

 

Input 4

 

P

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

Input 1

 

 

 

 

 

 

 

 

 

 

12

 

 

B+

2

Brake+

 

 

 

 

Input 2

 

 

B-

1

 

 

 

 

 

 

 

Brake-

 

 

 

 

Enable

15

 

Remove jumper if external

 

 

 

 

X8

 

 

 

 

 

 

 

 

 

 

 

16

 

regen resistor is connected

2

+RBint

 

 

 

 

 

 

 

 

 

 

Output 1

Digital1

 

FB1

1

-RB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

Regeneration

 

3

 

 

 

 

 

 

Output 2

Digital2

 

+RBext

 

 

 

 

 

resistor

 

4

 

 

 

 

 

 

2

 

FB2

n.c.

 

 

 

Fault RA

 

 

 

 

 

 

 

 

 

 

 

Safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

Fault RB

 

 

circuit

 

 

 

 

 

 

 

 

 

 

 

FN

1

 

 

 

X0A

X5

 

 

 

 

encoder-

 

L1

 

 

 

 

 

 

 

 

FN

2

 

 

 

 

 

ROD

 

 

L2

 

 

 

 

 

 

 

evaluation,

 

FN

3

 

 

 

 

 

 

SSI

 

 

 

L3

 

 

 

 

 

 

 

slave/master

 

 

4

 

 

 

 

 

Ma./SI.

 

 

 

 

 

 

 

 

 

 

 

 

 

PE

 

 

 

 

 

amplifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

X4

X6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

+24 Vdc

 

 

 

 

 

 

COM1/COM2

 

 

3

 

 

 

 

 

 

 

PC

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

24 Vdc Com

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply unit

 

 

 

 

X0B

X7

 

 

 

 

PE-connection (protective earth)

 

 

 

 

 

 

 

 

 

 

 

 

Master

24V DC

 

L1 L2 L3 PE

DC+DC- DC+DC-

 

earth connection (panel)

 

 

 

 

contactor

 

 

 

shield connection via plug

 

 

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shield connection at the front panel

 

FH

 

 

 

 

 

 

 

 

 

 

 

shielding if cable

is longer than 20cm

PE L1 L2 L3

to other amplifiers

45

Page 57
Image 57
Schneider Electric 17S Series manual Connection diagram for Lexium 17S, Gnd

17S Series specifications

Schneider Electric, a global leader in digital transformation of energy management and automation, has unveiled its innovative 17S Series designed for enhancing operational efficiency and sustainability in various industries. The 17S Series is a range of monitoring and control systems that integrates advanced technologies to enable seamless management of energy use, providing businesses with greater control over their energy consumption.

One of the main features of the 17S Series is its user-friendly interface that simplifies system navigation and operation. The graphical display provides real-time data and analytics, allowing users to monitor energy consumption patterns and identify areas for improvement. This enhanced visibility into energy usage facilitates informed decision-making, helping organizations reduce costs and increase productivity.

The 17S Series is built on advanced internet of things (IoT) technology, which allows for remote monitoring and management through cloud-based platforms. This connectivity ensures that users can access their energy management systems from anywhere at any time, optimizing their operations even when they are not on-site. Moreover, the integration with smart devices enhances automation capabilities, enabling systems to respond to changes in energy demand dynamically.

Another notable characteristic of the 17S Series is its compatibility with a variety of energy sources, including renewable energy options such as solar and wind. This flexibility supports organizations in their sustainability goals, as they can easily incorporate clean energy solutions into their operations. Schneider Electric’s commitment to sustainability is further evidenced by the energy efficiency measures embedded into the 17S Series, which minimize waste and reduce the overall carbon footprint.

The 17S Series also includes comprehensive security features to protect sensitive data and mitigate risks associated with cyber threats. Robust encryption and authentication protocols ensure that only authorized personnel can access control settings and operational data, maintaining the integrity of the system.

In conclusion, Schneider Electric's 17S Series stands out with its cutting-edge technologies, user-centric design, and commitment to sustainability. By providing real-time monitoring, IoT connectivity, and compatibility with renewable energy sources, the 17S Series empowers businesses to optimize their energy management strategies for a more efficient and sustainable future. As organizations increasingly focus on energy efficiency and reducing their environmental impact, the 17S Series emerges as a vital tool in achieving these objectives.