76
Warning Messages
Warning
Identification
and Description
A warning is generated when a non-fatal fault occurs. Non-fatal faults allow the
drive to remain enabled and the fault relay contact to remain closed. Either of the
programmable digital outputs can be programmed to indicate that a warning
condition has been detected. The cause of the warning is presented as an
alphanumeric code on the drive’s front panel LED disp la y; these warning code s are
identified and described in the following table.
Warning
Code Designation Explanation
n01 I²t warning Current threshold set by “I²t Message” parameter
was exceeded.
n02 Regen power Power threshold set by “Max Regen Power”
parameter was exceeded.
n03 Following Fault Following error threshold set by “Following Error”
parameter was exceeded.
n04 Response monitoring Response monitoring (fieldbus)is active.
n05 Mains phase Mains phase missing. Can be disabled for single
phase operation with the “Mains Phase Missing”
parameter.
n06 Sw limit-switch 1 Passed software limit-switch 1.
n07 Sw limit-switch 2 Passed software limit-switch 2.
n08 Motion task error A faulty motion task was started.
n09 No “Home” reference point Motion task started with no “Home” reference
point set.
n10 Positive Limit Positive limit-switch activated.
n11 Negative Limit Negative limit-switch activated.
n12 Default values Only HIPERFACE®: motor default values loaded.
n13 SERCOS interface SERCOS interface not functioning correctly.
n14 HIPERFACE®-reference
mode Attempt to reset while HIPERFACE®-reference
mode was active.
n15 Table error Velocity current table INXMODE 35 error
n16 ... n31 Reserved reserved
n32 Firmware beta version The firmware is not a released beta version
A Reset RESET is active at DIGITAL IN x