2.9Acoustics
Drive acoustics are measured as overall
LWt(spec) == LW + 0.1Pt + 0.3 < 4.0 (Bels) where
LW =
pt == Value of discrete tone penalty
dLt =
All measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially
Table 6: | Drive level acoustics | |
| ||
Acoustic mode | ||
|
|
|
Idle |
| Operational |
|
|
|
1.6 bels (typ) |
| 2.2 bels (typ) |
|
|
|
2.10Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 7: | Electromagnetic immunity |
|
| |
|
|
|
|
|
|
|
| Performance | Reference |
Test |
| Description | level | standard |
|
|
|
| |
Radiated RF immunity | 80 to 1,000 MHz, 3 V/m, | A | EN | |
|
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse modulation @ 200 |
|
|
|
| Hz |
|
|
|
|
|
| |
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on external I/O | B | EN | |
|
|
|
| |
Surge immunity | ± 1 kV differential, ± 2 kV common, AC mains | B | EN | |
|
|
|
| |
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 | A | EN | |
|
| kHz sine |
|
|
|
|
|
| |
Voltage dips, interrupts | 0% open, 5 seconds | C | EN | |
|
| 0% short, 5 seconds | C |
|
|
| 40%, 0.10 seconds | C |
|
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
|
14 | Lyrion Series IDE Product Manual, Rev. E |