Table 3: | 146GB standard model DC power requirements |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| 146GB standard model | 146GB standard model | ||
|
|
|
| 3.0 Gbit mode | 6.0 Gbit mode | ||
|
|
|
|
|
|
|
|
|
|
| Notes | (Amps) | (Amps) | (Amps) | (Amps) |
|
|
|
|
|
|
|
|
Voltage |
|
|
| +5V | +12V [2] | +5V | +12V [2] |
|
|
|
|
|
|
|
|
Regulation |
|
| [5] | ±5% | ±5% [2] | ±5% | ±5% [2] |
|
|
|
|
|
|
| |
Avg idle current DC |
| [1] [7] | 0.35 | 0.14 | 0.36 | 0.14 | |
Maximum starting current |
|
|
|
|
|
| |
|
|
|
|
|
| ||
(peak DC) DC | 3σ | [3] | 0.52 | 1.18 | 0.53 | 1.19 | |
(peak AC) AC | 3σ | [3] | 0.77 | 2.30 | 0.82 | 1.93 | |
| 3σ |
|
|
|
|
| |
Delayed motor start (max) DC | [1] [4] | 0.56 | 0.04 | 0.57 | 0.06 | ||
Peak operating current (random read): |
|
|
|
|
|
| |
|
|
|
|
|
| ||
Typical DC |
| [1] [6] | 0.45 | 0.36 | 0.48 | 0.33 | |
Maximum DC | 3σ | [1] | 0.48 | 0.36 | 0.52 | 0.33 | |
Maximum (peak) DC | 3σ |
| 1.08 | 1.18 | 1.14 | 1.16 | |
Peak operating current (random write) |
|
|
|
|
|
| |
Typical DC |
|
| 0.50 | 0.26 | 0.53 | 0.24 | |
Maximum DC | 3σ |
| 0.52 | 0.27 | 0.56 | 0.25 | |
Maximum (peak) DC | 3σ |
| 0.98 | 1.18 | 1.06 | 1.18 | |
Peak operating current (sequential read) |
|
|
|
|
|
| |
Typical DC |
|
| 0.85 | 0.16 | 0.87 | 0.13 | |
Maximum DC | 3σ |
| 0.88 | 0.16 | 0.92 | 0.14 | |
Maximum (peak) DC | 3σ |
| 1.12 | 0.28 | 1.16 | 0.26 | |
Peak operating current (sequential write) |
|
|
|
|
|
| |
Typical DC |
|
| 0.80 | 0.16 | 0.83 | 0.13 | |
Maximum DC | 3σ |
| 0.83 | 0.16 | 0.87 | 0.14 | |
Maximum (peak) DC | 3σ |
| 1.00 | 0.30 | 1.06 | 0.28 | |
|
|
|
|
|
|
|
|
[1]Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val- ues. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]For +12 V, a
[3]See +12V current profile in Figure 17.
[4]This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.
[5]See paragraph 7.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.
[6]Operating condition is defined as random 8 block reads.
[7]During idle, the drive heads are relocated every 60 seconds to a random location within the band from
Savvio 10K.3 SAS Product Manual, Rev. G | 23 |