Z
X
YZ Y
X
Figure 8. Recommended mounting
7.5.4.2Vibration a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
5 - 500 Hz, swept sine: 0.5 G (zero to peak)
10 - 500 Hz, random: 0.00051 G2/Hz Vibration may be applied in the X, Y, or Z axis.
b.
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency
5 - 500 Hz, swept sine: 0.75 G (zero to peak)
10 - 500 Hz, random: 0.00029 G2/Hz
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Savvio 15K.3 SAS Product Manual, Rev. A | 33 |