5.2.2Format command execution time

 

ST9300653SS

ST9146853SS

 

ST9300553SS

ST9146753SS

 

ST9300453SS

ST9146653SS

Maximum (with verify)

57 minutes

29 minutes

Maximum (without verify)

29 minutes

15 minutes

Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to the Initiator (excluding connect/disconnect).

When changing sector sizes, the format times shown above may need to be increased by 30 minutes.

5.2.3

General performance characteristics

 

Sustained transfer rate

144 to 193 MiB/s **

 

 

151 to 202 MB/s

SAS Interface maximum instantaneous transfer rate

600 MB/s* per port

 

 

(dual port = 1,200 MB/s*)

Logical block sizes

 

 

512 (default), 520, 524 and 528

 

Read/write consecutive sectors on a track

Yes

Flaw reallocation performance impact (for flaws reallocated at format time using the

Negligible

spare sectors per sparing zone reallocation scheme.)

 

Average rotational latency

2.0 ms

*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.

**MiB/s x 1.048 = MB/s

5.3Start/stop time

The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied.

If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.

The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec- onds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch on the drive.

12

Savvio 15K.3 SAS Product Manual, Rev. A

Page 20
Image 20
Seagate ST9300453SS, ST9300653SS manual Start/stop time, Format command execution time, General performance characteristics