Seagate ST9408114AB, ST9808211AB manual Acoustics, Electromagnetic immunity, Drive level acoustics

Models: ST9808211AB ST9100823AB ST9408114AB ST960822AB

1 40
Download 40 pages 24.3 Kb
Page 18
Image 18

2.11Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea- surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

Table 3:

Drive level acoustics

 

 

 

 

Acoustic mode

 

 

 

 

 

 

Idle*

 

Quiet Seek

Performance Seek

 

 

 

 

2.4 bels (typ)

 

2.6 bels (typ)

2.9 bels (typ)

2.6 bels (max)

2.8 bels (max)

3.1 bels (max)

 

 

 

 

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.

2.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the rradio frequency (RF) environments defined in the following table:

Table 4:

Electromagnetic immunity

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

 

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

ENV 50204: 95

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz

A

EN 61000-4-6: 97

 

 

sine

 

 

 

 

 

 

Power Frequency H-field

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

immunity

 

 

 

 

 

 

 

 

Voltage dips, interrupts

30% Reduction for 25 cycles

C

EN 61000-4-11: 94

 

 

>95% Reduction for 250 cycles

C

 

 

 

>95%, 0.5 cycles

B

 

 

 

 

 

 

A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.

2) No data loss.

B - 1) Unit self recovers without user intervention.

2) No data loss.

C - 1) Upset OK provided that unit will function after user intervention.

12

Momentus 5400.2 Blade Server Product Manual, Rev. B

Page 18
Image 18
Seagate ST9408114AB, ST9808211AB, ST960822AB, ST9100823AB manual Acoustics, Electromagnetic immunity, Drive level acoustics