Sears 153.336862 40 GALLON PROPANE (L.P.) Customer Responsibilities, Product Specifications

Models: 153.336466 40 GALLON 153.336162 153.336262 40 GALLON SHORT 153.336762 30 GALLON PROPANE (L.P.) 153.336362 30 GALLON 153.336566 50 GALLON 153.336962 50 GALLON PROPANE (L.P.) 153.336862 40 GALLON PROPANE (L.P.)

1 32
Download 32 pages 8.88 Kb
Page 5
Image 5
CUSTOMER RESPONSIBILITIES

CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING

TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

PRODUCT SPECIFICATIONS

 

 

 

 

RECOVERY

MINIMUM

 

DIMENSIONS

 

TANK

TYPE

INPUT

RATE GALS.

VENT PIPE

DIAMETER

IN INCHES (mm)

MODEL

CAPACITY

O F

RATE

PER HOUR

INCHES

INCHES

HEIGHT TO

NUMBER

IN GALS (LTRS)

GAS

(Btu/hr)

@ 90°F RISE

(mm)

(mm)

JACKET TOP

153.336162

30 (114)

NATURAL

32,000

30.6

3" (76) or 4" (102)

18 1/2" (470)

43 3/4" (1,111)

 

 

 

 

 

 

 

 

153.336262

40 (151)

NATURAL

35,500

35.4

3" (76) or 4" (102)

20" (508)

47 1/4" (1,200)

 

 

 

 

 

 

 

 

153.336362

30 (114)

NATURAL

35,500

34.9

3” (76)

16” (406)

57 1/2” (1,461)

 

 

 

 

 

 

 

 

153.336466

40 (151)

NATURAL

35,500

35.4

3" (76)

18 1/2" (470)

55 1/2" (1,410)

 

 

 

 

 

 

 

 

153.336566

50 (189)

NATURAL

35,500

35.4

3" (76)

20" (508)

56 1/2” (1,435)

 

 

 

 

 

 

 

 

153.336762

30 (114)

PROPANE

35,500

34.9

3" (76)

16" (406)

57 1/2” (1,461)

153.336862

40 (151)

PROPANE

35,500

35.4

3" (76)

18 1/2" (470)

55 1/2” (1,410)

 

 

 

 

 

 

 

 

153.336962

50 (189)

PROPANE

35,500

35.4

3" (76)

20" (508)

56 1/2” (1,435)

 

 

 

 

 

 

 

 

5

Page 5
Image 5
Sears 153.336862 40 GALLON PROPANE (L.P.), 153.336566 50 GALLON Customer Responsibilities, Product Specifications