Sears 625.34823 specifications Electric Power Outlet for Your, Fasten the Power Cable and Plug

Models: 625.34823

1 24
Download 24 pages 2.77 Kb
Page 14
Image 14

I SECTION 3 I STEP BY STEP GUIDES TO INSTALL

I

ELECTRIC POWER OUTLET FOR YOUR

12. FILTER

The filter works on 24 volt, 60 Hz electric power. The included transformer changes standard 120 volt AC

house power to 24 volts.You must plug the transformer into a 120 volt outlet only. Be sure the outlet is always "live" so spmeone cannot turn it off by mistake.

FASTEN THE POWER CABLE AND PLUG IN

13. THETRANSFORMER

Looking at FIG. 14, fasten the 2 power cable lugs (1 under each screw) to the transformer as shown.

Tighten both screws, then plug the transformer into the outlet.

NOTE: When you plug in the transformer, 12:00 AM and SU begin to flash in the face plate display.

14. SANITIZING THE WATER FILTER

Care is taken at the factory to keep your filter clean and sanitary, Materials used to make the filter

will not infect or contaminate your water supply, and will not cause bacteria to form and grow. However, if sanitizing is needed, do the following.

Press and hold button [] on the face plate

a.until RCHG be-_ginstoflash in the face plate display, starting a backwash.

After 5 to 10 minutes, press button [] again to start fast

rinse. Wait about 1 minute, THEN TURN OFF WATER TO THE FILTER AT THE MAIN SUPPLY VALVE.

Press button [] once more to return the valve to service.

Carefully remove the large plastic clip at the

bll

filter valve inlet (FIG. 7, page 10) and pull the adaptor out.

CONNECTING TRANSFORMER

Transformer

i

I

-

r--

\_/ _ Power Cable (Hook either lead

under either transformer terminaL)

dll

Carefully reconnect the plumbing.

 

e.Turn on the water supply.

f.Open the nearest filtered water faucet until you can smell chlorine, then close the faucet.

DO NOT USE WATER FOR ABOUT 45 MINUTES.

NOTE: If bypass valve, Item No. 42/65-3437 is install- ed, or if plumbing is too rigid to move, also disconnect

gll

After the 45 minutes, see step a to start a backwash. The filter will complete this backwash in about 35 minutes.

the outlet side and move the filter away from plumbing.

Put 1 teaspoon (0.1 ounce) of calcium

C.hypochlorlte into the valve inlet as far as possible.

NOTE: You can buy calcium hypochlorite in tablet or

granular form using trade names such as Perchloren and HTH.

While the filter is backwashing, do step 15. Then make the timer settings beginning on page 15.

ha

When the backwash is over, open filtered

 

water faucets until chlorine odor is gone, then

 

close.

15. TURN ON THE GAS (OR ELECTRIC) SUPPLY TO THE WATER HEATER AND

LIGHT THE PILOT.

14.

Page 14
Image 14
Sears 625.34823 specifications Electric Power Outlet for Your, Fasten the Power Cable and Plug, Sanitizing the Water Filter