Sears 625.34842 owner manual SR 17 shows

Models: 625.34842

1 64
Download 64 pages 35.17 Kb
Page 21
Image 21

SECTION 5

SERVICE TECH. INFORMATION

II

5A.TROU B LES H OOTI N G

CORRECT SWITCH DISPLAYS

-p

VALVE CYCLE STATUS

Valve in service, fill, brining, back- wash or fast rinse position

Valve rotating from one position to another

°Press the SELECT button and hold 3 seconds un- til...

SR 17 shows. _

JCODEI

This code identifies the softener nominal capacity

While in this diagnostic screen, the following in-

formation is available and may be beneficial for

various reasons. This information is retained by

the computer from the first time electrical power

is applied to the face plate.

--Press [_ to display the number of days this

face plate has had electrical power applied.

--Press [_ to display the number of regenera- tions initiated by this face plate since the SR code

number was entered.

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the following as needed.

Return the present time display: Press the SELECT button.

Change the SR number: To display the correct SR number, press the{_UP or DOWN {_ button. Press SELECT, and reset the tim_ _

NOTE:

If the face plate is left in a diagnostic display (or a flashing display when setting times or hardness), present time automatically returns if a button is not pressed within 4 minutes.

FACE PLATE REPLACEMENT: Be sure the valve is

in service

position

(observe

valve cycle

indica-

tor) when

replacing

the face

plate.

/flO

If, after installing and programming the replace- ment face plate, the valve is not in service position, do the following to assure correct cycle orientation, or timing, between the face plate and valve.

Use the MANUAL ADVANCE procedures, page 22.

With

the

RECHARGE NOW

button,

advance

through

the

recharge

cycles until

the

valve

stops in

service

position, and

RECHARGE no

longer flashes

in the

timer.

 

 

 

 

CAM /,

NOTE: The valve motor may automatically drive through several valve positions while searching for service. If an error code occurs, unplug the trans- former, then plug in again.

21

Page 21
Image 21
Sears 625.34842 owner manual SR 17 shows