Sears 625.34842 owner manual Service TECH. Information 5A.TROU B LES H Ooti N G, Wiring Schematic

Models: 625.34842

1 64
Download 64 pages 35.17 Kb
Page 19
Image 19

SECTION 5

SERVICE TECH. INFORMATION

II

5A.TROU B LES H OOTI N G

Keep this manual with your water softener. If repairs are needed, the SelWice technician must have the

informadon on the following pages. For telephone assistance, call toll free, 1-800-426-9345.

WIRING SCHEMATIC

IIRCUIT BOARD

 

TRANSFORMER

 

ii

 

 

24VAC

 

 

VAC

li'

 

 

 

110

 

 

 

 

 

 

 

 

NO

 

 

 

Wh

.0-"_ POSITION SWITCH

 

 

I=

 

0

 

 

grn

NO

 

()

__

Shield

 

 

 

 

 

 

 

 

BINE

 

 

 

 

ENSOR

 

 

 

 

 

UP button

f

display "7

Sears Water Line

for CustomerAssistance

1-800-426-9345 _ _._ ...............

J

ON/OFF-HOLD button "

SELECT button

DOWN

 

(Recharge Tonight-Now)

button

 

ALWAYS MAKE THESE INITIAL CHECKS FIRST

 

1.Does the time display show the correct time of day?

-If display is blank, check power source to the softener.

-If time is flashing, power was off for over 6 hours. The softener resumes normal operation but regen- erations occur at the wrong time.

-If an error code (Example: Err 03) shows in the face

plate display, go to Azdomatic iZ/ectromic Dia/qmos-

tics.

2.Plumbing bypass valve(s) must be in Full Service position.

3.The inlet and outlet pipes must connect to the softener valve inlet and outlet respectively.

4.Is the transformer plugged into a "live", grounded wall outlet, and is the power cable fastened securely?

5.The valve drain hose must be flee of kinks and sharp bends, and not elevated over 8 ft. above the floor.

REMOVE THE TOP COVER AND SALT TANK COVER

6.Is there salt in the storage tank?

7.Is the brine tubing connected? (See water flow diagrams).

8.Is the brine valve float set right? (See page 22).

9.Press the SELECT button 2 times to display the hardness setting. Be sure it is the correct setting for

the household's water supply. (Make a hardness test of the raw water and compare with the hardness setting. Also test a soft water sample to verify if a problem exists.) Press SELECT twice more to return the time of day display.

If you do not find the problem after making initial checks, do the Mamlal Initiated Electronic Diagnostics, and the

Manual Advance Regeneration Check.

19

Page 19
Image 19
Sears 625.34842 owner manual Service TECH. Information 5A.TROU B LES H Ooti N G, Wiring Schematic