Sears 758.14451 owner manual Troubleshooting, Sears Retail store

Models: 758.14451

1 16
Download 16 pages 56.11 Kb
Page 13
Image 13
Troubleshooting

Troubleshooting

--.,.,.,,..,.,

"

Trouble

Probable Cause

Remedy

Unit wilt not run.

Unit wil_ not shut off.

Unit will not dry out completely

Bottle continues to empty.

Unit is not emptying.

o Humidity level is too high

-No power

*Float is not free

Water is present in the system

High humidity or low temperature resulting in

istow evaporation

Air is entering water reser- voirs.

Dirty filter

Reservoir cap plunger missing post in bottom of cabinet.

Raise humidistat setting

Check 120 volt power source

Free float from obstruction

,This is normal. A small amount of water remains in the cabinet.

Allow unit to continue opera- tion.

Check "E-Z-Fill Side-Caps" to

ensure tightness.

Check for leak in water bottle.

Are gaskets for "E-Z-FillSide- Caps" in place (see repair parts fist).

Change to a fresh new fi}ter.

Check orientation of bottle. Reposition so that reservoir cap plunger is depressed by post in bottom of cabinet.

Unit runs and shuts off before bottle is

empty

* Humidity level is too high

. Unit is not setup on a level

surface (Float will not sense water at the rear of

the cabinet.

,Raise humidistat setting (if possible)

Position unit level (Some car-

pet padding may allow unit to set lower on the left side than

the right side due to the weight of the water bottle on left side.

Install coasters under left cast- ers.)

CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from

Sears Retail store,

Use of other water treatment products may damage the filter elements.

Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.