Troubleshooting | " |
Trouble | Probable Cause |
Remedy
Unit wilt not run.
Unit wil_ not shut off.
Unit will not dry out completely
Bottle continues to empty.
Unit is not emptying.
o Humidity level is too high
-No power
*Float is not free
•Water is present in the system
•High humidity or low temperature resulting in
istow evaporation
Air is entering water reser- voirs.
Dirty filter
Reservoir cap plunger missing post in bottom of cabinet.
Raise humidistat setting
•Check 120 volt power source
•Free float from obstruction
,This is normal. A small amount of water remains in the cabinet.
•Allow unit to continue opera- tion.
•Check
•ensure tightness.
Check for leak in water bottle.
•Are gaskets for
•Change to a fresh new fi}ter.
•Check orientation of bottle. Reposition so that reservoir cap plunger is depressed by post in bottom of cabinet.
Unit runs and shuts off before bottle is
empty
* Humidity level is too high
. Unit is not setup on a level
surface (Float will not sense water at the rear of
the cabinet.
,Raise humidistat setting (if possible)
•Position unit level (Some car-
pet padding may allow unit to set lower on the left side than
the right side due to the weight of the water bottle on left side.
Install coasters under left cast- ers.)
CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from
Sears Retail store,
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.
t3