Connecting The Oven
Gas Supply
Installation of this oven must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
In Canada the oven must be installed in accordance with the current CGA Standard
Codes for Gas Burning Appliances and Equipment and/or local codes.
In The Commonwealth Of Massachusetts
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
A "T" handle type manual gas valve must be installed in the gas supply line to this appliance.
A flexible gas connector, when used must not exceed a length of three (3) feet / 36 inches.
GAS SUPPLY CONNECTION:
A QUALIFIED SERVICEMAN OR GAS APPLIANCE
INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer according to the instructions given below in section h.
NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL GAS SERVICE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 POUNDS PER SQUARE INCH (P.S.I.) LIQUIFtED PETROLEUM (L.P.)/PROPANE GAS SUPPLY LINE MUST HAVE A LP. GAS PRESSURE REGULATOR. INLET PRESSURES IN EXCESS OF 0.5 P.S.I. CAN DAMAGE THE APPLIANCE PRESSURE REGULATOR AND OTHER GAS COMPONENTS IN THIS APPLIANCE AND CAN RESULT IN A GAS LEAK.
a.A GAS CUTOFF VALVE SHOULD BE PUT IN AN ACCESSIBLE LOCATION IN THE SUPPLY LINE
AHEAD OF THE UNIT, FOR TURNING ON AND TURNING OFF GAS SUPPLY. If the unit is to be
connected to house piping with flexible or
metal connectors for gas appliances, CONNECTOR NUTS MUST NOT BE CONNECTED DIRECTLY TO PIPE THREADS. THE CONNECTOR MUST BE
INSTALLED WITH ADAPTORS PROVIDED, WITH THE CONNECTOR.
b.The house piping and/or oven connector used to connect the oven to the main gas supply must be clean, free of metal shavings, rust, dirt and liquids (oil
or water). Dirt, etc. in the supply lines can work its way into the range manifold and in turn cause failure of the gas valves or controls and clog burners.
CAUTION: DO NOT LIFT OR MOVE THE WALL OVEN BY THE DOOR HANDLES.
C.Turn off all 3ilots and main gas valve of other gas appliances.
d.Turn off main gas valve at meter.
e.Before connecting the unit, apply pipe thread compound approved for LPG to all threads.
Connect unit to gas supply. Use a backup wrench when pulling on end of regulator.
CAUTION: MAKE SURE THE CONNECTION DOES NOT SHIFT THE REGULATOR PIPE OUT OF POSITION.
g.Turn on main gas valve at meter, and relight pilots at other gas appliances.
h.Apply a
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF
ALL RESIDUE.
Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when
cold.
BEFORE LIGHTING ANY BURNER, SEE THAT ALL PACKING MATERIALS HAVE BEEN REMOVED FROM THE UNITS.
WARNING
Gas leaks may occur in your system and result in a dangerous situation. Gas leaks may not be detected by smell alone. Gas suppliers recommend you purchase and
install an UL approved gas detector. Install and use in accordance with the manufacturer's instructions.