AIR SHUTTER - OVEN BURNER

a.The approximate length of the flame of oven burner is a 1/2 inch distinct blue flame, figure 4.

b.Oven burner flame can be checked as follows, without burner baffle in place:

1.Yellow flame on burner - open burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 5.)

BURNER BAFFLE

1/2"

FIGURE 4

. Distinct blue flame but lifting - close burner air shutter to the point where it will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 5.)

High Altitude Notice

The specified gas burner ratings typically apply to elevations up to 2000 feet. For higher altitudes, the rates may need to be reduced to achieve satisfactory operation. A local certified gas servicer will be able to advise if a reduction is necessary.

FLAME

LOCK SCREW 3

AIR SHUTTER 2

ORIFICE HO

FIGURE 5

-6-

Page 6
Image 6
Sears 8101 P590-60 High Altitude Notice, AIR Shutter Oven Burner, Burner Baffle, Flame Lock Screw AIR Shutter Orifice HO