Orifice Conversion

1.FROM NATURAL GAS TO LP/PROPANE GAS:

a.Change the appliance pressure regulator from natural to LP setting. (See figure 6, 7 or 8).

b.Screw the burner orifice hoods down tight against the pins. (See figure 9B). Use care to not over tighten. Over tightening can damage the coaxial pin inside the orifice hood.

NOTE: On units using Eaton Oven Safety Valve, screw the valve orifice hood down tight against the valve body. (See figure 9D). It is important that the hood be turned down as far as it can go to insure that complete conversion has occurred.

C.Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold.

NOTE: Correctly adjusted sealed burners, can have flames that will lift or blow without a pot over the burner. These should be adjusted with a pot in place.

2, FROM LP/PROPANE GAS TO NATURAL GAS:

a.Change the appliance pressure regulator from LP to natural setting. (See figure 6, 7 or 8).

b.Screw the burner orifice hoods away from the pins. (See figure 9A). Approximately 1 1/2 to 2 turns.

NOTE: On units using Eaton Oven Safety Valve, screw the burner orifice hoods away from pin (see figure 9C). Approximately 1 1/2 to 2 turns.

Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold.

NOTE: Correctly adjusted sealed burners, the flame will lift or blow without a pot over the burner. These should be adjusted with a pot in place.

SERVICE - PARTS INFORMATION

WHEN YOUR RANGE REQUIRES SERVICE OR REPLACEMENT PARTS, CONTACT YOUR DEALER OR AUTHORIZED SERVICE AGENCY. PLEASE GIVE THE COMPLETE MODEL AND SERIAL NUMBERS OF THE RANGE WHICH IS LOCATED ON THE RANGE MODEL NUMBER PLATE.

FOR ALL TOP BURNER AND

FOR EATON

OVEN SAFETY

VALVE

CONVERSION

OVEN SAFETY VALVE

CONVERSION

(EXCEPT

EATON

VALVE)

 

 

 

 

 

FECE

HOOD

ART I_ 9219-983-0

FIGURE

9A

FIGURE 9B

FIGURE 9C

FIGURE 9D

NATURAL

GAS

LP GAS

NATURAL GAS

LP GAS

SETTING

SETTING

SETTING

SETTING

-8-

Page 8
Image 8
Sears 8101 P590-60 Orifice Conversion, From Natural GAS to LP/PROPANE GAS, From LP/PROPANE GAS to Natural GAS