TS2000
Key Functions
Engineer Reset | Control Panel Links |
1.Enter your engineer’s code default 1234, you are now in Engineer’s Mode
2.Press 0 in quit to unset.
Loading Defaults
1.Power down panel battery and mains, close LK2
2.Power up panel battery and mains
3.Enter 1234 and open LK2
4.The panel is back to Factory Default Programming.
Bell Test/Walk Test
Please refer to page 19
Memory Default Values
When a CP is shipped from the factory the memory data default parameters are set to:
1.Circuits: The Type and Attributes Parameters set will depend upon the number of circuits detected;
2.Passcodes: Engineer 1234: Master 5678: Others unspecified;
3.Timers: Exit 25 secs: Exit Settling 5 secs: First Entry 30
secs: Second entry 30 seconds: Bell delay 5 mins:
Bell Duration 20 mins: Comms Delay 1.5 mins: Lights
Off 5 secs: Mains Off 10 secs: Menu Timeout 30 secs: Double Knock 10 secs.
These values will also be restored if a Factory Restart occurs.
Link | Functions |
LK1 | Open: Printer to monitor Network |
| activity |
| Closed: Normal; Printer normal |
| and responds to keypad |
| commands |
LK2 | Open: Normal; |
| power up |
| Closed:Factory restart at power |
| up |
LK3 | DC3 Monitor; Leave closed |
JP5 | Normally fitted with links |
| Remove and fit Engineer’s REM if |
| required. |
JP9 | Open: Novram battery isolated |
| Closed: Normal; Novram battery |
| connected |
JP13 | Open: Normal |
| Closed: Soft reset |
|
|
Fuses
Fuse | Value | Use |
PSU F1 | 1AQB | Low voltage |
|
| ac input |
PSU F2 | 2A QB | 12V external |
|
| (auxiliary) |
|
| supply |
Fuseholder | 1A QB | Network 12V |
|
| supply |
Fused terminal | 1A | Mains input |
Block |
|
|
496529 Issue A | 13 of 20 | TS2000 |