Additional Equipments

TS2000

Additional Equipments

Remote Data Transfer

Ward Control Unit (WCU): When fitted the WCU will allow a group of circuits, which are designated a Ward, to be Set and Unset using Exit and Entry routes separate from the system. The WCU is connected to the outputs and circuits of a REM or a NU and will require a separate 12V supply.

Printer: An Epson printer P40-S may be connected temporarily to the CP or to the SlB to provide printout records. Other printers that accept RS232 serial data may be permanently connected to the SIB if permanent records are required.

Power Supply Unit: All power can be supplied from the TS2000 CP internal Power Supply Unit but in large systems it may be necessary to fit additional power supply units. The PSU150 has been designed for use with the TS2000 system and consists of a PSU and battery (supplied separately) and it may also have a Node Unit and a Relay Unit fitted in its enclosure.

Output Modules (OM): If remote indicators or Mimic Panels containing LEDs are required then Output Modules type CPA6.OM may be connected to the CP. Each OM unit will drive up to eight LEDs and the units may be interconnected for large displays. The system may be programmed so that the LEDs indicate circuit condition or alarms and ward status if wards are programmed.

Extension loudspeakers: The REM contain a small sounder unit to provide an indication of the system status. If the volume of the sounder is insufficient (e.g. a louder exit sound is required) then an extension speaker may be fitted to the NU and this will require a Loudspeaker Drive Unit type LSD1 to be connected between the NU and the loudspeaker. A separate 12V power supply will also be required.

Relay Unit: The NU and REM programmable outputs will provide current limited drive for various facilities but in many cases it will be necessary to isolate the system from the external equipment by driving via relays. Relay Units type RM3A provide two relays, which may be energised by NU or REM programmable outputs, and which provide two sets of ’clean’ change over contacts. The unit may be fitted separately or in a PSU150 case.

When fitted with a Digimodem type DC3M the system may be programmed from a remote location, and log data transferred to it, using a dedicated program installed in a Personal Computer at that location. The use of this facility is protected by a series of passcodes and user menus.