TS2000
Equipment
System Specification
Supply Voltage: |
| 240V + or - 10% 30W 50 Hz |
Battery: |
| 12V 6Ah |
Zones: |
| 128 maximum |
Outputs: |
| 128 remote 8 local maximum |
Unit Dimensions: | CP | L 395 x W 280 x D 100mm |
(boxed) NU/WCU | L 145 x W 85 x D 50mm | |
REM |
| L 220 x W 145 x D 40mm |
Unit Weights: | CP | 4 kg |
NU/WCU | 220 g | |
REM |
| 430 g |
Environment: |
| 0 - 40° C 95% RH n.c. |
Control Panel (CP)
The CP comprises electronic units inside a white polycarbonate lid and a steel base which are factory assembled to hinge on the left but which may be reversed if required.
The Base Unit contains the mains input terminals and a mains transformer. Space is provided for a battery and also for a Digital Communicator. Cable entry points are provided as follows:
1.Four 20mm knockouts top and bottom;
2.Two Holes for plastic trunking fitted with plastic inserts top and bottom;
3.13mm round knockouts fitted in the plastic inserts;
4.Four 20 mm round holes in the back.
The lid unit contains the Main Control printed circuit board (pcb) and the Power Supply pcb which are secured on posts and on which are fitted terminals for external connections. Option Boards (SIB and PIB) may also be fitted to the main board.
Under normal conditions the unit can be positioned at any location as access will only be required for maintenance.
Power Supply
The CP is fitted with the system combined Power Supply and Battery Charger Unit and a battery which will provide power during a mains failure. Power arrangements are as follows:
1Mains input 240V +/- 10%
2Battery 12V 6Ah Sealed Lead Acid rechargeable
type which is normally float charged at about 13.6V;
3.System regulated supply 12V with a maximum output of 1.5A. The internal supply is load protected and the external supply fused;
4.System internal 5V supply;
5. Standby operation during a mains failure depends upon battery size and the size of the system. Current consumption may be calculated as follows:
(a)CP: normal 150mA; alarm 500mA;
(b)Each NU (with 4 circuits connected): normal 33mA;
(c)Each REM (with 4 circuits connected): normal 33mA;
(d)Each NU/REM in alarm - load depends upon outputs used;
6Power supply fault monitoring is for loss of mains supply, low system supply voltage and low battery voltage;
7Fuses are fitted on the PSU as follows:
(a)F1: 1A QB for low voltage a.c. input;
(b)F2: 2A QB for 12V dc external output;
8
9A 1A fused terminal block is fitted for the mains input.
TS2000 | 6 of 20 |
496529 Issue A