4-6

Parameter Setup Mode

This mode is used when the operator sets the heater control system

parameters.

(1) Setup items and parameters

The setup items and parameters are listed in the table below.

*1 Display only, ON/OFF key is ignored.
(2) Entering the parameter setup mode

Press the ON/OFF key, key, and key on the heater control

panel at the same time to enter to the parameter setup mode.

The 1st setup item in the parameter setup mode will be displayed.

Note: # will be blinked.
No. Item ItemDisplay
(upperline)
Parameters
Display
(lowerline)
Description Initialvalue
1Temperatureunit UNIT CELSIUS
FAHRENHEIT -CELSIUS
2Heatsuspending
timeafter printing DELAYTIME 00 to 30 MINUTE UNIT:minute 05MINUTES
3
Standbyheating
timeafter
completionof
DELAYTIME
STANDBYTIME 0,30, 60, 90, 120,
ENDLESS Unit:minutes 30
4Versiondisplay VERSION FW=vv.rHW=vv.r Displayonly -
5Diagnostics DIAGNOSTICS NO, YES
NO: Doesnot perform
thediagnostics.
YES:Performs the
diagnostics.
NO
6Display language LANGUAGE ENGLISH
JAPANESE -ENGLISH
7Exitofsetupmode EXIT YES, NO
YES:Exits from the
parametermode.
NO: Doesnot exit from
theparameter mode.
YES
# UNIT
* CELSIUS