Preparing the central unit for use
Preparing the central unit for use
Setting up the central unit on a flat surface or mounting it into a rack
Make sure that the air vents are not covered or blocked.
Place the central unit on a flat surface as shown.
For information on how to mount the central unit into a 19” rack, refer to the detailed instruction manual.
Connecting the central unit to the mains
CAUTION
Product damage due to unsuitable mains cables or power outlets!
An unsuitable power supply can damage the product.
Only use the recommended mains cable (see page 4) for connecting the product to the mains.
Only use
Only use mains cables with a
First connect the mains cable to the mains socket D.
Connect the mains cable to the mains.
The central unit is now ready for operation.
D
IN
PORT II | PORT I |
|
|
| |
52.8V | 1.75A | 50/60Hz 240W |
8 9
Setting up the conference system
Connecting the conference units to the central unit
You can connect up to 15 conference units to each of the central unit’s connection sockets PORT II 8or PORT I 9. The maximum number of conference units that can be used in one cable string depends on the overall cable length connected to a port (see page 7).
The following describes the procedure for one cable string. If necessary, repeat these steps for a second cable string.
Place the conference units at the corresponding seats.
Put out a sufficient number of system cables in the required lengths.
If necessary, calculate the maximum length of the cable string in order to ensure that all conference units connected in the string are supplied with a voltage of at least 35 V (see page 7).
8 ADN CU1