Structuring and controlling the conference system

Structuring and controlling the conference system

Structuring the conference system

The ADN conference system is suitable for conferences with up to 400 conference units. For safe operation of the conference system, make sure that all conference units are supplied with a voltage of at least 35 V! The voltage supplied depends on the number of connected conference units and on the cable lengths. The standard cable length between the central unit or power supply and the first conference unit is 80 m max. and the standard cable length between the individual conference units is 2 to 5 m.

If these cable lengths are observed, safe operation of conference systems with the following number of conference units is ensured:

small conference systems comprising only an ADN CU1 central unit

30-40 conference units connected in simple strings

large conference systems comprising an ADN CU1 central unit and a max. of 15 ADN PS power supplies

max. 400 conference units connected in simple strings or in ring topology

per ADN PS power supply

60-70 conference units connected in simple strings

30-40 conference units connected in ring topology

If cable lengths are shorter, it might be that more conference units can be used.

ADN D1 delegate units and ADN C1 chairperson units can be combined in an arbitrary order. The number of chairperson units, however, is limited to 10 max. per conference system. All components of the conference system are interconnected using SDC CBL RJ-45 system cables.

Small conference system with simple cabling

For small conference systems with approx. 30-40 conference units, you require one ADN CU1 central unit for controlling the conference. The conference units are interconnected in two cable strings which are directly connected to the central unit.

ADN CU1

PORT

II

 

PORT I

ADN CU1

max. 80 m

52.8 V

max. 40

ADN D1/ADN C1

1

2

3

...

20

 

approx.. 2-5 m

 

approx.. 2-5 m

 

 

 

 

 

 

 

 

 

>35 V

6 ADN CU1