Connecting the amplifier/mixing console

The two audio outputs of the twin receiver are available as transformer balanced XLR-3M sockets. You can connect an amplifier or a mixing console to each audio output.

Connect the amplifier/mixing console to the XLR-3M sockets AF OUT B (receiver RX B) or AF OUT A (receiver RX A).

Via the operating menu, adapt the level of the audio output (AF OUT A and/or AF OUT B) to the input of the amplifier/mixing console (see “Adjusting the audio output level” on page 58).

Service interfaces

The two service interfaces DATA B and DATA A are only required for servicing purposes.

Mounting the twin receiver into a 19” rack

For mounting the twin receiver into a 19” rack, use the supplied GA 2 rack adapter. The GA 2 rack adapter consists of:

y 2 rack mount “ears”

y4 recessed head screws M 3x6

Hook the two rack mount “ears” to the rear panel of the twin receiver.

Secure the rack mount “ears” to the twin receiver using two of the supplied recessed head screws (M 3x6) respectively.

Slide the twin receiver into the 19” rack.

Secure the rack mount “ears” to the rack.

Mounting the antennas

When rack-mounting the twin receiver, use the GA 3030 AM antenna mount (optional accessory) for mounting the telescopic antennas to the front of the GA 2 rack adapter. The GA 3030 AM antenna mount consists of:

y 2 BNC extension cables (screw-in BNC socket to BNC connector ) y 2 antenna holders

y 2 plain washers y 2 nuts

48