Charging a stethoset receiver/ spare accupack

• Insert the receivers into the charging compartments of the

L 151-10, the accupacks remain in the receivers.

• Alternatively, individual

BA 151 spare accupacks can be charged in small charging compartments integrated into the side of the main charging compartments for the receivers. However, it is only possible to insert either an individual accupack or a receiver containing an accupack into the charging compartment (not both together).

Starting the charging process

By pressing the button, the „normal“ charging process begins. The red LED goes off briefly and the charging process is indicated by the red control LEDs at the occupied charging com- partments. The automatic charging process (timer-controlled) will be completed after 8 hours. The device then switches to trickle charging.

Essential notes

The charging process („CHARGE“) cannot be interrupted. By pressing the button again, the charging timer is reset and the charging process starts over again.

A power failure also resets the charging timer and the charging process starts over again.

Switch off the receivers before starting the charging process! For additional information on the use of the receivers, please refer to the corresponding operating instructions.

Place the charging unit on a flat surface in order that the contacts of the receivers are securely connected to the charging unit.