Specifications

Specifications

Modulation

Frequency range

Switching bandwidth Transmission frequencies

RF output power

Frequency stability

Nominal/peak deviation

Signal-to-noise ratio

THD

(at 1 kHz, nominal deviation) AF frequency response Noise reduction system

Input sensitivity at nominal deviation

Low-cut frequency (–3 dB) Sensitivity

Power consumption

(without LC display illumination)

Operating time

wideband FM

range 1

(L):

470 to 638 MHz

range 2

(N/N-US):

614 to 798 MHz/614 to 697.9 MHz

range 3

(P):

776 to 866 MHz

up to 184 MHz

frequency bank “FIX” with up to 59 factory-preset frequencies

frequency bank “VAR” with 20 freely selectable frequencies (frequencies tuneable in steps of 5 kHz)

switchable,

typ.: 50 mW (PWR.Hi) 10 mW (PWR.LO) 10 mW (PWR.LoI)

±10 ppm in the specified temperature range

±40 kHz/±56 kHz

typ. 110 dB(A)rms

< 0.3 %

60 to 20,000 Hz

Sennheiser HiDynplus

–40 dBu = 7.75 mV

adjustable (flat, 120 Hz)

adjustable in steps of 1 dB from –30 to +40 dB

PWR.LO: approx. 150 mA (10 mW) at 1.5 V

PWR.HI: approx. 220 mA (50 mW) at 1.5 V

PWR.LoI: approx. 220 mA (10 mW) at 1.5 V

PWR.LO: approx. 11 hrs

PWR.HI: approx. 5.5 hrs

PWR.LoI: approx. 5.5 hrs

29