Sennheiser SZI 1029-10 Electrical Accessories, GZL 1019 A5, GZL 1019 A10, N.B. „Infra-Red

Models: SZI 1029-10 SZI 1029

1 59
Download 59 pages 21.91 Kb
Page 20
Image 20
ELECTRICAL ACCESSORIES

ELECTRICAL ACCESSORIES

GZL 1019 A1

Connection cable

 

For connecting the radiator to the transmitters SI 1013,

 

SI 29-5 or SI 1029. Length 1 m.

GZL 1019 A5

Connection cable

 

For connecting the radiator to the transmitters SI 1013,

 

SI 29-5 or SI 1029. Length 5 m.

GZL 1019 A10

Connection cable

 

For connecting the radiator to the transmitters SI 1013,

 

SI 29-5 or SI 1029. Length 10 m.

GZV 1019

BNC coupler

 

For connecting two connection cables GZL 1019 A1, -5, -10.

N.B.: „INFRA-RED

If you consider using a transmission system with high power IR radiators

PLANNING BROCHURE“

SZI 1029 the „Infra-red Planning Brochure“ from Sennheiser is available.

FROM SENNHEISER

Besides in-depth information on infra-red transmission technology it

 

contains application examples and lists with combinations and overviews

 

for infra-red system planning.

Since we are continually trying to improve our products it may happen that some technical alterations are made on the described products after these operating instructions have gone to press. We apologise for any inconvenience.

TECHNICAL SPECIFICATIONS

SZI 1029 (SZI 1029-10)

 

 

Number of radiator diodes

144 (288)

 

Approximate radiating power

5 W (10 W)

 

Wavelength of radiated

 

 

infra-red light approx.

 

880 nm

 

Carrier frequency range

30 kHz - 6 MHz

 

IR input

 

50 mV - 3 V / approx. 5 k

 

Input/output connections

BNC sockets

 

Switching treshold for

 

 

 

automatic on/off function

50 mV

 

Operating voltage

...-120

85 - 265 V ± 10 %, 50 - 60 Hz

 

 

...-EU

85 - 265 V ± 10 %, 50 - 60 Hz

 

 

...-UK

85 - 265 V ± 10 %, 50 - 60 Hz

 

 

...-24

24 V min., ideally 25 - 35 V DC

 

Current consumption

...-120

approx. 610 mA (1A) with 120 V

 

 

...-EU

approx. 350 mA (700 mA) with 230 V

 

 

...-UK

approx. 350 mA (700 mA) with 240 V

 

 

...-24 approx. 1.6 A (3.2 A) with 24 V DC

 

Stand-by

 

60 mA max.

 

Mains fuse for 120/230/240 V

2 A, anti-surge type

 

 

 

in the IEC mains socket

 

Fuse for 24 V

 

DC 2 A, anti-surge type

 

Dimensions in mm

 

250 x 180 x 80 (250 x 288 x 80)

 

Weight

 

approx. 2.1 kg (approx. 3 kg)

 

Supply schedule

 

1 radiator

 

 

 

1 mains cable (2.5 m)

 

UL-No. (only for 120 volt

 

 

USA version)

 

to be advised